CT# 04 - Turbogenerator

1979-80 Westinghouse multi-stage extraction, back pressure steam turbine and Mitsubishi 20pole, 3 phase, 60HZ generator with a generating capacity of 29,412 KVA; 0.85 PF; 25,000KW at 13,800 volts.  A Woodward electronic/hydraulic governor is used to maintain the desired control.  Oil for the turbine and generator bearing lubrication and for the hydraulics of the governor system is supplied by a Lawrenco lube oil console.

Rated KW

25000

Initial Temp.

371 deg C
700 deg F

Initial Press.

4238 kPa
615 PSI

RPM

3600

No. 1 Ext. Press.

1204 kPa
175PSI

No. 2 Ext. Press.

1110 kPa
161 PSI

Max kW

29411

Steam Temperature

380 deg C
700 deg F

Instruction Book

CG-9478

Exhaust Pressure

515 kPa
75 PSI